Enzyme tower
Ceramic Tile lining with epoxy over a
coat of Primer Aroon 20
(Caustic Temp 30 to 35 PH 11 to 12)
Chlorine Tower
Two layers of F.R.P. Lining in Arolister.
Two layers of Ceramic Tile lining in Arolister
(Caustic Temp Ambient PH 1 to 10)
Chlorine Di-Oxide Tower
Two layers of F.R.P. Lining in Arvinyl
- 1100 S. Two layers of Ceramic tile lining in Arvinyl
- 1100 S
(Caustic Temp 30 to 35°C PH 1 to 12)
Hypotower / High density Tower
Ceramic Tile lining in Aroon
20 over a coat of primer (Calcium Hyp A Temp
30 to 40°C PH 6.5 to 7.5)
Pulp/Bleaching Chests
Ceramic Tile lining in Cement/ Sand Mortar/Pointing
- Aroon 20 (Caustic Temp
30 to 40°C PH less than 11)
White water tank/ Foam Breaker tank
Ceramic Tile lining in Cement/ Sand Mortar/Pointing
- Aroon 20 [Caustic 35
to 40°C PH 4 to 5]
Floor/Foundation below Paper machine
Ceramic Tile lining in Aroon
20 over a coat of primer
Vats
Ceramic Tile lining in Aroon
20 over a coat of primer [Caustic 60°C to
70°C PH Less than 10]
Demineralised Water treatment Plant
A.R. Tile Lining in Aroplex
K / Arfurane R
over mastic membrane - Aroprimer
/ Arocompound
Effluent Treatment Plant
A.R. Brick Lining in Aroplex
K / Arfurane R
over mastic membrane - Aroprimer
/ Arocompound
Chlorination Plant - Floors
5 mm thick Monolithic Epoxy Screeding over
a coat of primer and two seal coats - Aroon
10
ANTI CORROSIVE COATINGS
Structures, Tanks Vessels, Pipelines,
Utility Pipelines, Chimneys, Conveyor Belt &
Structures,
Roof/Shades, Utilities etc
|